Specifications

Specifications

STRUCTURE +
  • RCC framed structure
BLOCKWORK +
  • Autoclaved Aerated Concrete (AAC) Block
JOINERY +
  • Main Door - Teak wood frame with architrave and threshold, fitted with PU finished teak veneered flush shutter.
  • Bedroom and Toilet door – Hard wood frame fitted with prelaminated flush shutter.
  • Balcony door and Window - UPVC frame with clear glass
  • Ventilator - UPVC frame with frosted glass
FLOOR FINISH +
  • Living / Dining / Bedroom / Kitchen - 1200 X 600mm Vitrified tiles
  • Toilet /Service - 600 x 600mm Anti-skid Ceramic tiles
  • Balcony - 1200x200mm Anti-skid Ceramic tiles
  • Car park - Granolithic floor finish for Stilt and Basement parking
  • Staircase - Granite finish upto 1st floor and Ceramic tile for all other floors
  • Entrance lobby at Stilt / Ground floor - Granite
  • Corridor and Lift lobby at all other floors - 600 x 600mm Vitrified tiles
WALL & CEILING FINISH +
  • Toilet wall - 1200 x 600mm Ceramic tile upto ceiling height
  • Kitchen dado - 600 x 300mm Ceramic tile upto 2' height from countertop
  • Internal walls - Gypsum plaster finish with emulsion paint Asian / Dulux or equivalent
  • External walls - Combination of texture paint and weather shield paint Asian / Dulux or equivalent
  • Ceiling - Putty finish with emulsion paint Asian, Dulux or equivalent
HANDRAIL +
  • Staircase - Mild Steel handrail
  • Balcony - Toughened glass with aluminium powder coated railing system
  • Window - Half height Mild Steel grill
KITCHEN & LOFT +
  • Loft - Provision in Kitchen and Master Bedroom
  • Kitchen platform - Full body Vitrified Marbonite countertop
  • Kitchen sink - Stainless steel sink with drain board, Nirali or equivalent
SECURITY +
  • Main door - Digital lock - Yale or equivalent, Door viewer and Door security Chain
  • Bedroom door - Godrej lock or equivalent
PLUMBING +
  • Sanitaryware - Wall-hung water closet with dual flush concealed cistern; 2-way concealed diverter with spout and overhead shower, American Standard or Roca or equivalent
  • CP fittings - American Standard or Roca or equivalent
ELECTRICAL +
  • Internal wiring - Flame Retardant Low Smoke wires
  • Switches and sockets - Anchor Roma / Siemens or Equivalent
  • MCBDB - Havells / Anchor Panasonic or Equivalent - Provision for AC in Living and all Bedrooms - Provision for Geyser in all toilets - Provision for exhaust in all toilets - Provision for chimney exhaust in kitchen - DG Power Back up for fans, lights, 5amp power sockets limited to 600W for 2BHK & 800W for 3 BHK
GENERAL +
  • STP and WTP of suitable capacity shall be provided
  • Lifts - Johnson or Kone or Equivalent